New Product Launch

【New Product Launch】Trans SARS-CoV-2, Influenza A/B and Respiratory Syncytial Virus Assay

Time:2022-07-25 10:03:29 View:

We are proud to announce the launching of DV105 Trans SARS-CoV-2, Influenza A/B and Respiratory Syncytial Virus Assay!

 

Why detect ARS-CoV-2, Influenza A/B and Respiratory Syncytial Virus?

While the global spreading of COVID-19 is posing a major public health threat, the common seasonal respiratory infections still continue to circulate. Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), influenza A, influenza B, and respiratory syncytial virus (RSV) cause acute respiratory infections with similar clinical manifestations. The infection management and treatment strategies, however, differ depending on the pathogen. Rapid identification of the virus that is causing the infection is important to ensure correct measures for infection control and treatment.

 

What is Trans SARS-CoV-2, Influenza A/B and Respiratory Syncytial Virus Assay?

The kit is designed for detecting SARS-CoV-2, Influenza A Virus, Influenza B Virus and Respiratory Syncytial virus RNA in specimens using multiplex real time RT-PCR technology with primers and probes targeting the conserved regions of ORF1ab genes of SARS-CoV-2, MP gene of Influenza A virus, NEP gene of Influenza B virus and M gene of Respiratory Syncytial virus.

Simultaneously, this kit contains an endogenous control (The internal control RNase-P gene is detected by VIC channel) to monitor the process of specimen collection, nucleic acid extraction and PCR and reduce false negative results.


Kit Contents

Component Name

Main Constituents

Specifications

 (48   tests)

Specifications

 (200   tests)

PCR Reaction Mix

Reaction buffer,   dNTPs, etc.

600 μL×1 tube

1250 μL×2 tubes

PCR Enzyme Mix

Reverse   transcriptase, RNase inhibitor, Taq DNA polymerase, uracil-DNA glycosylase

48 μL×1 tube

200 μL×1 tube

PCR Primer / Probe

Mix

Primers and probes   for SARS-CoV-2,

Influenza A Virus,   Influenza B Virus,

Respiratory Syncytial   virus and the internal control-RNase P gene

312 μL×1 tube

1300 μL×1 tube

Positive Control

In vitro transcribed   RNA for SARS-CoV-2, Influenza A Virus, Influenza B Virus, Respiratory   Syncytial virus and the internal  control-RNase P gene

50 μL×1 tube

200 μL×1 tube

Negative Control

RNase-free Water

50 μL×1 tube

200 μL×1 tube


Product Information

Minimum Detection Limit

500 copies/mL

Accuracy

Positive Detection Rate

100%

Negative Detection Rate   for Negative Control

100%

Analytical   Specificity

The kit was evaluated   for cross-reactivity with four influenza A virus (H1N1, H3N2, H5N1, H7N9) ,  two influenza B virus (Yamagata, Victoria), Adenoviruses, seven Human   coronavirus(SARS-CoV-2, HCoV-HKU1, HCoV-229E, HCoV-OC43, HCoV-NL63, MERS-COV   and SARS-COV), Respiratory Syncytial virus (A/B strain), Cytomegalovirus,   Enterovirus virus (EV71,CA16), Human parainfluenza virus, Measles virus,   human metapneumovirus, Mumps virus, Respiratory syncytial virus, rhinovirus,   Bacillus pertussis, Chlamydia pneumoniae, Corynebacterium, Escherichia coli,   Haemophilus influenzae, Lactobacillus, Catamola, Non-toxic Mycobacterium   tuberculosis, Mycoplasma pneumoniae, Neisseria meningitidis, Neisseria   gonorrhoeae, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis,   Streptococcus pneumoniae, Streptococcus pyogenes, Streptococcus saliva and   human genome. The results indicated that the influenza A virus (H1N1, H3N2,   H5N1, H7N9) was tested as positive of influenza A/B , the influenza B   (Yamagata, Victoria) was tested as positive of influenza A/B , the SARS-CoV-2   was tested as positive of SARS-CoV-2, respiratory syncytial virus (A/B   strain) was tested as positive of respiratory syncytial virus, and others   were tested as negative. The reference standards with and without mucin were   both found positive. The negative samples were tested as negative.

Precision

Negative detection   rate of the negative samples

100%

positive detection   rate of the strong positive samples

100%

positive detection   rate of the limited positive samples

≥95%

Specimen Types

nasal swab specimens

Storage

-20±5°C away from light for 12 months

Shipping

Dry ice (-20°C)


Features

●  4 tests in 1 setup: SARS-CoV-2, Influenza A virus, Influenza B virus and Respiratory Syncytial virus

●  UDG and dUTP minimize carry-over contamination.

●  High sensitivity.

●  Suitable for the currently widely used fluorescence PCR instrument.

●  CE marked.

 

The product has the Declaration of Conformity in vitro diagnostic medical devices Directive (98/79/EC) IVDD of EU. It indicates that our products meet the requirements of the relevant EU directives, has completed the registration with the EU competent authorities, and meet the access conditions for the EU market.


Declaration of Conformity in vitro diagnostic medical devices Directive (98/79/EC) IVDD

CopyRight 2022 TransGen Biotech Co., Ltd. All Rights Reserved          京ICP备07502849号-1       京公网安备 11010802016705号