From RT to qPCR: Pipetting Made Fully Visible
In qPCR experiments, the accuracy of the pipetting step directly affects the reliability of the final data. With the high well density of 96-well and 384-well plates, and the fact that reaction systems are mostly colorless and transparent, operators find it difficult to judge by eye alone whether pipetting has been completed. Missed additions, duplicate additions, or incorrect sample additions occur frequently. Moreover, once abnormal amplification results appear, the time spent troubleshooting pipetting errors often exceeds the time needed to simply repeat the experiment. To address this long-standing operational pain point for laboratory personnel, TransGen Biotech has officially launched four new traceable-series products covering the entire workflow from reverse transcription (RT) to real-time quantitative PCR (qPCR), extending visual tracing technology from qPCR to the reverse transcription step and achieving full-process tracing from RT to qPCR.
Not Just qPCR—RT Is Also "Visible"
There are already some traceable qPCR premixes on the market, but the selection of traceable reverse transcription reagents is very limited, with most offering only a single type that struggles to cover different experimental scenarios.
This time, TransGen Biotech has upgraded its RT reagents with tracing capabilities—AT342, AU342, and AW312 are each supplemented with a blue traceable dye, allowing movement to be tracked by the naked eye. When used together with AQ641, the bright blue cDNA template and the light purple qPCR SuperMix mix to form a dark violet-blue system, achieving seamless tracing from RT to qPCR and delivering true "full-process visualization."

Traceable RT-PCR
Three traceable reverse transcription reagents, covering different experimental scenarios.
1. Basic Version: All-in-One SuperMix
TransScript® Visual All-in-One First-Strand cDNA Synthesis SuperMix for qPCR (One-Step gDNA Removal) (AT342)
Simply add gDNA Remover, template RNA, and water. cDNA synthesis and genomic DNA removal are completed simultaneously in a single step. Optimized primer ratios ensure consistent reverse transcription efficiency across different RNA concentrations, with high short-fragment cDNA synthesis efficiency—done in 15 minutes.
2. Thermostable Version: 5-Minute Rapid Reverse Transcription
TransScript® Uni Visual All-in-One First-Strand cDNA Synthesis SuperMix for qPCR (One-Step gDNA Removal) (AU342)
Reaction temperature: 42–65°C. Can accurately detect even pg-level low-abundance templates—the best choice when time is tight.
3. Anti-Inhibitor All-Round Version
TransScript® IV Visual One-Step gDNA Removal and cDNA Synthesis SuperMix (AW312)
Suitable for degraded RNA, with good resistance to residual inhibitors. Synthesis length can reach up to 20 kb, reaction temperature 42–65°C—rely on it when sample quality is poor.
Traceable qPCR
Dual-color traceable qPCR premix—making amplification visible too.
PerfectStart® IV Visual Green qPCR SuperMix (AQ641)

Good User Experience
Contains blue and light purple traceable dyes, dual-color indication.

3 Antibody Blocking
High specificity
High sensitivity

Efficient Amplification
High amplification efficiency
Good linear relationship

Pre-mixed Universal Passive Reference Dye
Corrects well-to-well signal errors.

Good Stability
37°C for 7 days
20 freeze-thaw cycles

Accurate Data
Divalent cation buffer
Reduces primer dimer formation.
Visible and Accurate as Always
Will adding dye compromise product performance? TransGen Biotech conducted a comprehensive comparison between the traceable versions (AT342, AU342, AW312) and the original non-traceable versions (AT341, AU341, AW311)—the conclusion is: there is almost no difference! Moreover, in more stringent qPCR quantitative experiments, TransGen's traceable version (AQ641) outperforms similar products.
AT342 Performance Demonstration
Amplification of Different Genes by Reverse Transcription

Using AT342 and its corresponding non-traceable-dye version (AT341), reverse transcription was performed on 100 ng of rice RNA samples, followed by qPCR amplification (AQ641).
High Reverse Transcription Efficiency

Using AT342 and its corresponding non-traceable-dye version (AT341), reverse transcription was performed on serially diluted (1000 ng–0.1 ng, 10-fold gradient) human RNA samples, followed by qPCR amplification (AQ641).
Wide species applicability

Using AT342 and its corresponding non-traceable-dye version (AT341), reverse transcription was performed on RNA templates from different species, followed by qPCR amplification (AQ641).
AU342 Performance Demonstration
Amplification of Different Genes by Reverse Transcription

Using AU342 and its corresponding non-traceable-dye version (AU341), reverse transcription was performed on 100 ng of rice RNA samples, followed by qPCR amplification (AQ641).
High Reverse Transcription Efficiency

Using AU342 and its corresponding non-traceable-dye version (AU341), reverse transcription was performed on serially diluted (1000 ng–0.1 ng, 10-fold gradient) human RNA samples, followed by qPCR amplification (AQ641).
Wide species applicability

Using AU342 and its corresponding non-traceable-dye version (AU341), reverse transcription was performed on RNA templates from different species, followed by qPCR amplification (AQ641).
High-GC-content templates

Using AU342 and its corresponding non-traceable-dye version (AU341), reverse transcription was performed on human RNA samples with high GC content, followed by qPCR amplification (AQ641).
AW312 Performance Demonstration
Amplification of Different Genes by Reverse Transcription

Using AW312 and its corresponding non-traceable-dye version (AW311), reverse transcription was performed on 100 ng of rice RNA samples, followed by qPCR amplification (AQ641).
High Reverse Transcription Efficiency

Using AW312 and its corresponding non-traceable-dye version (AW311), reverse transcription was performed on serially diluted (1000 ng–0.1 ng, 10-fold gradient) human RNA samples, followed by qPCR amplification (AQ641).
Wide species applicability

Using AW312 and its corresponding non-traceable-dye version (AW311), reverse transcription was performed on RNA templates from different species, followed by qPCR amplification (AQ641).
AQ641 Performance Demonstration
High amplification efficiency, good linear relationship

Using TransGen and similar products, amplification curves and standard curves were obtained by amplification with serially diluted plasmid DNA (250 pg/μl–0.025 pg/μl, 10-fold dilution) carrying the human housekeeping gene GAPDH as the template.
Excellent amplification curve morphology

Using TransGen and similar products, qPCR amplification was performed with human and rice cDNA as templates, respectively.
Amplification of high-GC content templates

Using TransGen and similar products, qPCR amplification was performed on high-GC-content cDNA templates from human and rice.
Compatible with different instruments

Using human cDNA as the template, amplification curves obtained from amplification on different instruments.
Good Stability

SuperMix can still amplify stably after storage at 37°C for 7 days and 20 repeated freeze-thaw cycles.
10×Sample Buffer Thermal Acceleration Stability

Sample Buffer can still amplify stably after storage at 37°C for 7 days.
Product Information
Category | Product Name | Catalog No. | Specification |
Traceable RT | TransScript® Visual All-in-One First-Strand cDNA Synthesis SuperMix for qPCR (One-Step gDNA Removal) | AT342 | 50/100/500 rxns |
TransScript® Uni Visual All-in-One First-Strand cDNA Synthesis SuperMix for qPCR (One-Step gDNA Removal) | AU342 | 100 rxns | |
TransScript® IV Visual One-Step gDNA Removal and cDNA Synthesis SuperMix | AW312 | 50/100 rxns | |
Traceable qPCR | PerfectStart® IV Visual Green qPCR SuperMix | AQ641 | 1/5×1/15×1/25×1 mL |